G506A
Rugged AI Accelerator with 4x M.2 PCIe Slot
Main Features
- 4× M.2 AI Accelerator Board (PCIe 3.0 x8)
- 2230/2242/2260/2280 card sizes
- Large aluminum heat sink
- AI module power control interface and thermal monitoring
- Onboard power buffer for impulse loads
- 11 status LEDs
- Up to -40 °C to +85 °C operating temperature
- Compliant with EN 50155 (railways)
- Long-term availability
CompactPCI Serial with four AIPU/NPU Modules
The G506A is a CompactPCI Serial expansion board featuring up to four Axelera AI Metis™ AIPU (Artificial Intelligence Processing Unit) or optionally Hailo AI modules to introduce and leverage sophisticated AI applications at embedded level (e.g. CCTV with object and anomaly detection). This solution will allow you to use all AIPU/NPU modules within a single software application and even distribute them to different instances of a virtualized computer solution.
Rugged AI Module Carrier for Railway Applications
The G506A complies with the EN 50155 standard for use in railway applications. A large, finned aluminum heat sink provides optimum heat dissipation for optimal performance.
Thermal Monitoring and Control
Thermal sensors allow for flexibility with specific user applications and thermal conditions.
This Product is Coming Soon
The G506A will be available once conformity assessments are completed.
Related Products
- AI Processing
- 4× M.2 2230/2242/2260/2280 socket 3 Key M (PCIe 3.0 x4)
- Available with either 1, 2 or 4 preassembled AI processors by Axelera or Hailo (optional)
- PCI Express: 1 × PCIe 3.0 x8, backplane
- Temperature measurement
- M.2 card control
- Supply voltage: +12 V (-10 % / +10 %)
- Power consumption: 60 W peak, maximum allowed power consumption per card: 11 W
- Dimensions: 3U, 4 HP
- Weight: 323 g (02G506A00)/334 g (02G506A01)/357g (02G506A02), with heat sink
- Cooling: Air cooling, forced convection, required airflow depending on assembled cards
- Protection rating: IP20
- Compliance level: This product is prepared for use in EN 50155 systems. Some parameters are system-dependent and are specified on system level.
- Operating temperature: -40 °C to +85 °C (EN 50155:2021, Tmax/PCB = +85 °C; designed for use in OT4+ST1 systems)
- Equipment location
- EN 50155:2021, location 1, closed electrical operating area
- EN 50155:2021, location 2, cabin and interiors
- Rapid temperature variations: EN 50155:2021, class H1, no requirements
- Storage temperature: -40 °C (EN 50155:2021) to +85 °C (EN 60068-2-2, Bb)
- Altitude: +3000 m max. (EN 50125-1:2014, class AX)
- Pollution degree: EN 50124-1:2017, class PD2
- Humidity: +55 °C and +25 °C, 100 % RH max. (EN 50155:2021)
- Shock: 30 ms @ 50 m/s² (EN 61373:2010/AC:2017-09, vehicle body, cat. 1, class B)
- Vibration: 10 min @ 2.02 m/s² (functional) and 5 h @ 11.44 m/s² (long-life) (EN 61373:2010/AC:2017-09, vehicle body, cat. 1, class B, double acceleration)
- Electrical safety
- EN 50155:2021
- EN 50153:2014 + A1:2017 + A2:2020
- EN 50124-1:2017
- EN ISO 13732-1:2008
- Fire protection: EN 45545-2:2020, EL9, HL3
- EMC emission
- EN 50121-3-2:2016 + A1:2019
- Regelung Nr. EMV 06 :2019-05-09 (2.0), Anhang E: Messung an Geräten, Schutzklasse S1
- Regelwerk 50.02.01 :2021-12-01, 12.3.2. EMV - Funk, prequalified according to electronic equipment tests defined by Deutsche Bahn EMV 06 standard, class S1, for risk minimization in finished vehicle test
- EMC immunity: EN 50121-3-2:2016 + A1:2019
- Protective coatings: EN 50155:2021, class PC2 (Any PCB protected on both sides)
- Useful life: 20 years (EN 50155:2021, class L4)
- Operating temperature: -40 °C to +70 °C (EN 50125-3:2003, class T2, cubicle, with class T2 maximum extended by 5 °C)
- Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C (EN 60068-2-2:2007, Bb)
- Altitude: +3000 m max. (EN 50125-3:2003, class AX)
- Pollution degree: EN 50124-1:2017, class PD2
- Humidity: 95 % RH max. (EN 50125-3:2003, building N.C.C., class T1/T2/TX)
- Humidity - Condensation: Non-condensing
- Shock: 11 ms @ 20 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
- Vibration: 2.3 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
- Electrical safety
- EN 50124-1:2017
- EN 62368-1:2014 + AC:2015
- EMC emission: EN 50121-4:2016+A1:2019
- EMC immunity: EN 50121-4:2016+A1:2019
- Operating temperature: -40 °C (EN 60068-2-1:2007, Ae) to +85 °C (EN 60068-2-2:2007, Be)
- Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C (EN 60068-2-2:2007, Bb)
- Altitude: +3000 m max. (EN 62368-1:2014 + AC:2015)
- Electrical safety: EN 62368-1:2014 + AC:2015
- Flammability (PCBs): UL 94 V-0
- EMC emission
- EN 55032:2015 + AC:2016 + A11:2020 + A1:2020 (multimedia equipment), class A (industrial environments)
- EN 61000-6-4:2019 (generic standard, industrial environments)
- EMC immunity
- EN 55035:2017+A11:2020 (multimedia equipment)
- EN 61000-6-2:2019 (generic standard, industrial environments)
- Tested with: Ubuntu 24.04 LTS