ME11
Single Pair Ethernet Extension Module
Hauptmerkmale
- Single pair Ethernet interfaces according to 100BASE-T1 and 1000BASE-T1 or
- Standard Ethernet interface according to 1000BASE-T
- Front I/O: 5x SPE or 5x GbE or 3x SPE + 2x GbE
- PTP support
- DIN rail or wall mounting
- -40 °C to +70 °C (+85 °C), fanless
Ethernet Extension for Modular Embedded Systems
The ME11 is a cutting-edge industrial Ethernet device designed for harsh environments. With its single pair Ethernet interfaces supporting both 100BASE-T1 and 1000BASE-T1, or standard 1000BASE-T connectivity options, this product provides unparalleled flexibility in a wide range of applications. The front I/O features five ports, offering a choice between SPE (Serial Peripheral Interface), GbE (Gigabit Ethernet), or a combination of three SPE and two Gigabit Ethernet. This versatility allows you to customize the solution to meet specific needs.
Modular System for Easy Configuration
Due to duagon's modular concept, the ME11 offers flexibility in built-to-order configurations. Via its extension connectors, the box can be easily combined with pre-fabricated CPU modules or other extension modules, for example a PSU or removable storage shuttles, providing additional features and short delivery times. In the modular system, the data transfer between the modules as well as the power distribution between the individual components takes place via the extension connectors standardized by duagon.
Long-Term Availability
Long-term availability ensures an extended product life and future-safety.
This Product is Coming Soon
The ME11 will be available once conformity assessments are completed.
Zugehörige Produkte
- Ethernet
- 2 × 100/1000BASE-TX, M12, X-coded, receptacle
- 3 × 100/1000BASE-T1, M12, single pair, receptacle
- For possible combinations see Ordering Information.
- LED: activity, link
- Dimensions: (W) 38 mm, (D) 144 mm, (H) 132 mm
- Weight: tbd
- Mounting
- DIN rail
- Rack in 19" cabinet
- Wall/flat surface
- Cooling: Air cooling, natural convection, airflow 0.4 m/s
- Protection rating: IP20
- Ethernet: IEEE 802.3-2022/Cor 1-2024 (100BASE-T1, 1000BASE-T1, 1000BASE-T)
- PTP (Precision Time Protocol): IEEE 1588-2019
- Connectors: M12 T1 (SPE) / M12 X-coded (standard GbE)
- Compliance level: This product is prepared for use in EN 50155 systems. Some parameters are system-dependent and are specified on system level.
- Operating temperature: -40 °C to +70 °C, +85 °C for 10 min (EN 50155:2021, class OT4, ST1)
- Equipment location: EN 50155:2021, location 2, cabin and interiors
- Rapid temperature variations: EN 50155:2021, class H1, no requirements
- Storage temperature: -40 °C (EN 50155:2021) to +85 °C (EN 60068-2-2, Bb)
- Altitude: +3000 m max. (EN 50125-1:2014, class AX)
- Humidity: +55 °C and +25 °C, 100 % RH max. (EN 50155:2021)
- Shock: 30 ms @ 50 m/s² (EN 61373:2010/AC:2017-09, vehicle body, cat. 1, class B)
- Vibration: 10 min @ 2.02 m/s² (functional) and 5 h @ 11.44 m/s² (long-life) (EN 61373:2010/AC:2017-09, vehicle body, cat. 1, class B, double acceleration)
- Pollution degree: EN 50124-1:2017, class PD3
- Electrical safety
- EN 50155:2021
- EN 50153:2014 + A1:2017 + A2:2020
- EN 50124-1:2017
- EN ISO 13732-1:2008
- Fire protection: EN 45545-2:2020, EL9, HL3
- EMC emission
- EN 50121-3-2:2016 + A1:2019
- Regelung Nr. EMV 06 :2019-05-09 (2.0), Anhang E: Messung an Geräten, Schutzklasse S1
- EMC immunity: EN 50121-3-2:2016 + A1:2019
- Protective coatings: EN 50155:2021, class PC2 (Any PCB protected on both sides)
- Useful life: 20 years (EN 50155:2021, class L4)
- Operating temperature: -40 °C to +70 °C (EN 50125-3:2003, class T2, cubicle, with class T2 maximum extended by 5 °C)
- Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C (EN 60068-2-2:2007, Bb)
- Altitude: +3000 m max. (EN 50125-3:2003, class AX)
- Humidity: 100 % RH max. (EN 50125-2:2002, control cabinet, class T1/T2/TX)
- Shock: 11 ms @ 20 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
- Vibration: 2.3 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
- Electrical safety
- EN 50124-1:2017
- EN 62368-1:2014 + AC:2015
- EMC emission
- EN 50121-4:2016+A1:2019
- EN 61000-6-4:2019
- EMC immunity
- EN 50121-4:2016+A1:2019
- EN 61000-6-2:2019
- Operating temperature: 0 °C (EN 60068-2-1:2007, Ae, temperature value in compliance with 6.6 b) to +60 °C (EN 60068-2-2:2007, Be)
- Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C (EN 60068-2-2:2007, Bb)
- Humidity: +55 °C and +25 °C, 90 % to 100 % RH (EN 60068-2-30:2005, Db)
- Electrical safety: EN 62368-1:2014 + AC:2015
- EMC emission: EN 55032:2015 + AC:2016 + A11:2020 + A1:2020 (multimedia equipment), class A (industrial environments)
- EMC immunity: EN 55035:2017+A11:2020 (multimedia equipment)
- duagon Yocto BSP
- Linux: Tested with: duagon Yocto BSP (Kirkstone 4.0, Linux kernel 5.15)